132: Fats and Oils - Chemistry LibreTexts

A triglyceride is called a fat if it is a solid at 25°C; it is called an if it is a liquid at that temperature These differences in points reflect differences in the degree of unsaturation and number of carbon atoms in the constituent fatty acids

Get a Quote

PentoMag® | Additive for HFO Boilers - Pentol

Fuel oil components with low melting point form molten ash components and stick to the surface of boiler walls superheaters reheaters and economizers Growing deposits set a long sequence of compensation actions into gear Heat transfer is reduced The gas temperature needs to be raised to keep the steam quality constant

Get a Quote

Vanadium-Containing Oil Ash Corrosion of Boilers Under

Oil ash corrosion occurs when vanadium-containing ash deposits on boiler tube surfaces become molten These molten ash deposits dissolve protective oxides and scales causing accelerated tube

Get a Quote

A steam dried municipal solid waste gasification and

The temperature of the swirl melting furnace reached about 1240°C when the gasification ER was 03 and the total ER was 11 At these conditions the fly ash concentration in the flue gas was 17 g·(Nm 3)-1 which meant over 95% fly ash was trapped in the furnace and discharged as slag 85% of Ni and Cr were bound in the slag as well as 60% of Cu The mass and energy balance analysis indicates that the boiler

Get a Quote

Cause of Boiler Tube Failures - Chicago Tube & Iron

Fuel ash corrosion is a high-temperature phenomenon in coal and oil-fired boilers In oil-fired boilers sodium sulfate combines with vanadium pentoxide to form a very corrosive coating of molten slag on the fireside tube surface of superheater and reheater tubes

Get a Quote

High Temperature Corrosion in Boilers - Bright Hub Engineering

High temperature corrosion in firing coal is mainly caused due to the presence of impurities like sulphur alkali metals and chlorine In fuel fired the main impurities are vanadium sulphur sodium and chlorine During combustion various species containing these impurity elements are produced in the form of vapors and condensed phases The of these reactions

Get a Quote

Heat Transfer Surface Fouling in Boilers - Bright Hub

The medium melting constituents are those with a melting temperature of around 900 to 1100 degree C which include FeS Na2SiO3 K2SO4 etc The high melting constituents form the bulk of the ash quantity and are SiO2 Al2O3 CaO MgO Fe2O3 etc The melting temperature of these constituents lies in the range of 1600 to 2800 degree C

Get a Quote

Ash Melting Behavior during Co-gasification of Biomass and

Depending on the origin and characteristics of the biomass used the combustion technology and conditions and the temperature of the there may be considerable sinter and

Get a Quote

An overview of problems and solutions for components

· Agglomeration is basically therelated problem of biomass-fired which are formed from high-sulfur and low-ash fuel agglomerate if they are prone to sulfating condition for long time The degree of sulphation varies with both time and It varies proportionally with increase in temperature and time

Get a Quote

(PDF) Chemical and Physical Characterization of Boiler Ash

The boiler ash was obtained from the boiler in the palm oil processing factory The chemical and physical characterization has been analyzed using X-Ray Fluorescence (XRF) X-Ray Diffraction (XRD)

Get a Quote

SH-RH Fireside Corrosion - Oil | Structural Integrity

Oil ash corrosion generally occurs as the result of the formation of low melting point liquid phase vanadium and vanadium-sodium based compounds For example sodium vanadyl vanadate (Na 2 O·V 2 O 4 ·5V 2 O 5) with a melting point of 1157°F is a commonly reported compound from the corrosive ash These low melting point compounds are corrosive to the protective oxides on the tube surfaces

Get a Quote

The Role of Fireside Corrosion on Boiler Tube Failures Part I

· The melting points of these compounds range between 1000F and 1550F depending on composition [4 5 6] The oil ash corrosion mechanism is similar to coal ash corrosion: a

Get a Quote

(PDF) Chemical and Physical Characterization of Boiler Ash

from Palm Industry Waste for Geopolymer Composite December 2013 Revista de Chimie -Bucharest- Original Edition- 64(12):1408

Get a Quote

Valmet debuts online ash analyzer to improve boiler

· The Valmet Recovery Analyzer measures the complete balance including ESP pH carbonate (CO 3) sulfate (SO 4) chloride (Cl) potassium (K) and sodium (Na) concentrations as well as calculating temperatures T0 T15 and T70 The ESP sample is taken from the drop shoot after the conveyor by a robust stainless-steel sampler dissolved in

Get a Quote

Ash Deposition in a Pulverized Coal-Fired Power Plant

The fabric mineralogy and of high-calcium deposits from the Agios Dimitrios pulverized-lignite power plant in northern Greece have been investigated as a key to the ability to improve the performance of the power plant All inner surfaces in the are covered with a layer of particulate matter showing various degrees of agglomeration or with fouling deposits Agglomerated

Get a Quote

PentoMag® | Additive for HFO Boilers - Pentol

Fuel components with low point form molten components and stick to the surface of walls superheaters reheaters and economizers Growing deposits set a long sequence of compensation actions into gear Heat transfer is reduced The gas temperature needs to be raised to keep the steam quality constant

Get a Quote

Evacuation of Slag Deposits on Boiler Tubes and Improving

The deposit that is formed on tube walls of the combustion chamber and on tubes of the radiative super heaters is tightly bound with the tube surface The particles formed in the fired are usually smaller Their deposition on cool surfaces of the mainly occurs on the radiative and convective superheaters

Get a Quote

Valmet debuts online ash analyzer to improve boiler

· The Valmet Recovery Analyzer measures the complete balance including ESP pH carbonate (CO 3) sulfate (SO 4) chloride (Cl) potassium (K) and sodium (Na) concentrations as well as calculating temperatures T0 T15 and T70 The ESP sample is taken from the drop shoot after the conveyor by a robust stainless-steel sampler dissolved in

Get a Quote

Ash-related issues during biomass combustion: Alkali

· For silicate -induced slagging ( fusion) the evolutions of composition of both the elements and minerals in the during combustion and existing problems in testing are overviewed Pseudo-4D phase diagrams of (Ma 2 O)-MaeO-P 2 O 5 -Al 2 O 3 and (Ma 2 O)-MaeO-SiO 2 -Al 2 O 3 are proposed as effective tools to predict

Get a Quote

The influence of ashing temperature on ash fouling and

Here the characteristics-related projects mainly involves particle size distribution composition morphology thermal analysis fusion and transformation properties of the inorganic components in This data revealed the effects of ashing temperature and burning time on the agglomeration behavior which influences the

Get a Quote